April 1999   Volume 1   Number 1


Chapter 4 of Forensic Fiber Examination Guidelines

Appendix A:
Suggested Standard Dye Mixtures

Standard dyes should be used to check eluent performance. The following list suggests some suitable mixtures but is not totally inclusive or exclusive. Any (simple) mixture of dyes separating in these eluents can be used.

Recommendations for Preparation of Standard Dye Mixtures:
Approximately 5 mg of each dye component is made up to a final volume of 25 mL with pyridine/water (4:3 v/v). Use until the supply is exhausted.

Solution A for eluents 1, 2, 3, 4, 9, 10, 12
Solway green G (CI Acid Green 25), Solway blue RNS (CI Acid Blue 47) and Naphthalene fast orange 2GS (CI Acid Orange 10).

Solution B for eluents 5, 7, 8
Supracet fast orange G (CI Disperse Orange 3), Supracet fast violet B (CI Disperse Violet 8) and Supracet scarlet 2G (CI Disperse Orange 1)

Solution C for eluent 6
Supracet fast orange G (CI Disperse Orange 3) and Supracet fast violet B (CI Disperse Violet 8).

Solution D for eluent 11
Solway green G (CI Acid Green 25), Supracet fast orange G (CI Disperse Orange 3) and Supracet fast violet B (CI Disperse violet 8).

Testing of Eluents and Extraction Solutions
Checks are carried out prior to use on eluent performance, and the extractants are tested to ensure that they have not been contaminated. Suggested TLC plates are Merck DC Alufolien Kieselgel 60F254 (7.5 × 5.0 cm). The standard dye and extraction solution are spotted side by side onto a TLC plate that rests on a hot plate set at approximately 70°C or is dried with a heat source such as a blow-dryer. They are spotted 1 cm from the base and eluted as described in section 7.0 (Analysis; click to view) of Chapter 4. The chromatogram is compared with previous stored tests to ensure that the separation is acceptable and that there are no visible bands obtained from the extraction solution. If unacceptable, fresh eluent/extractant is made and tested.

Back to the top